Skip to main content
  • Letter to the Editor
  • Open access
  • Published:

Three cases of anaphylaxis following injection of a depot corticosteroid with evidence of IgE sensitization to macrogols rather than the active steroid

Abstract

We present three cases with anaphylaxis after injection of a depot corticosteroid. First, the steroid was suspected as the elicitor, but after evaluation the excipient macrogol was found to be the elicitor. One of the patients had reactions to several unrelated drugs. Increased awareness of anaphylaxis to excipients such as macrogols is needed, especially when allergy tests for the active drug is negative and in patients with a history of repeated anaphylaxis to seemingly unrelated drugs. To establish the correct diagnosis it is important to test with the exact formulation of the culprit drug, as well as all the ingredients including excipients.

To the editor

Macrogols or polyethylene glycols (PEG) are polymers used as excipients in many different drugs including depot corticosteroid solutions for injection. We present 3 cases of anaphylaxis due to macrogol 3350 after injection of a depot corticosteroid for arthritis or tendinitis. Evaluation, including challenges, with the pure corticosteroid and lidocaine was negative. SPT and specific IgE for latex and chlorhexidine were negative. In all cases skin prick tests (SPT) showed sensitization to macrogol of varying molecular weights, while histamine release (HR) tests to macrogols were negative. Laxatives are the only products on the Danish market declaring the concentration of macrogol 3350. All three patients underwent open titrated oral challenge with the laxative Movicol JuniorR containing macrogol 3350 as the active component. Two of the three patients reacted with anaphylaxis. The third patient was only sensitized by SPT to macrogol 6000, and a challenge with a larger dose of macrogol 3350 is planned.

Case 1

A 46 year-old woman developed plantar pruritus, generalized urticaria, nausea and respiratory symptoms 30 min after injection with Depo-MedrolR (80 mg) and LidocainR due to Achilles tendinitis. The symptoms progressed with sensation of throat tightness, dysphagia and hypotension and she was treated with intramuscular epinephrine.

One month later, allergy testing was performed: SPT with Depo-MedrolR (containing macrogol 3350) was positive, while SPT with Solu-MedrolR (containing the same steroid component but no macrogol) was negative. Positive SPT to macrogol 6000 and Movicol JuniorR (containing macrogol 3350) were found by titrated SPT (Table 1). HR test for both the corticosteroids and macrogols were negative. Titrated intravenous challenge with Solu-MedrolR was negative. Five months after the anaphylactic reaction an open titrated oral challenge with Movicol JuniorR was positive with objective signs after the last dose (cumulative dose of 6.56 g macrogol 3350) including itching in the palms, rhinitis and conjunctivitis. Just before the challenge the SPT was repeated with Depo-MedrolR and Movicol JuniorR. The SPT was still positive for Movicol JuniorR but had become negative to Depo-MedrolR, and 1 year after the initial anaphylactic reaction both had become negative.

Table 1 Diagnostic summary of allergy tests

Case 2

A 57 year-old man was admitted to the Emergency Department with anaphylactic shock requiring treatment with epinephrine after an intraarticular injection with 80 mg Depo-MedrolR in the knee. Eight years earlier, he developed tachycardia, erythema and general discomfort after a corticosteroid injection in the shoulder with DiprospanR (another steroid drug for injection also containing macrogol 3350) and 4 years earlier he developed respiratory symptoms, palpitations and throat tightness with voice change immediately after a colonoscopy, where he had received pretreatment with MoviprepR, an osmotic laxative containing macrogol 3350.

The patient was referred for evaluation 2 years after the reaction to Depo-MedrolR. SPT with Depo-MedrolR, DiprophosR and Solu-MedrolR were negative and HR test for both the corticosteroids and macrogols were negative (Table 1). A titrated challenge with Solu-MedrolR was negative. SPT was positive for macrogol 20,000 (0.01 and 0.1%) and the patient developed generalized urticaria 2 h after the SPT. He had an open titrated oral challenge with Movicol JuniorR, and developed a systemic reaction after ingestion of cumulative 916.5 mg of macrogol 3350. He already had subjective symptoms after the first dose, but only developed objective symptoms including urticaria and angioedema immediately after the fourth dose. Six months later, his general practitioner initiated treatment with EscitalopramR, containing macrogol 400, and the patient developed urticaria a few minutes after ingestion of the first dose.

Case 3

A 63 year-old woman with arthritis developed general discomfort, a burning sensation in the soles, erythema spreading to the trunk and arms, respiratory symptoms and mild hypotension after intraarticular injections with 80 mg Depo-MedrolR and LidocainR in the wrist and finger joints. She was evaluated a few months later. SPT with Depo-MedrolR and Solu-MedrolR were negative, and intravenous challenge with Solu-MedrolR was negative. SPT was positive for macrogol 6000 but negative for other lower molecular weight macrogols including Movicol JuniorR. HR test for both the corticosteroids and macrogols were negative. The patient had a titrated open challenge with Movicol JuniorR, which was negative up to 6.56 g of macrogol 3350. A challenge with a higher amount of macrogol 3350 has not been performed due to severe co-morbidity.

Discussion

During the last year three patients have been referred to our clinic on suspicion of corticosteroid allergy due to anaphylactic reactions after depot corticosteroid injections. All tolerated challenge with the pure corticosteroid, but two were found to be oral challenge positive to the excipient macrogol 3350 while the third was sensitized in SPT. However, in the third case other elicitors were excluded and despite negative challenge with Movicol JuniorR up to 6.56 g anaphylaxis to macrogol was still suspected. As the clinical effect of osmotic laxatives is primarily in the gut and <2% is absorbed [1], the challenge dose was probably too low in this patient. Due to comorbidity we have not yet performed challenge with a higher dose of macrogol to verify the allergy. Only few case reports of anaphylaxis to macrogols in corticosteroid solutions can be found in the literature [25]. Macrogols are used in many drugs and other products including electrolyte lavage solutions, tablets and topical products, and anaphylaxis have been described to many different formulations via many different administration routes [6]. In patients with severe allergic reactions to chemically unrelated drugs, it is important to consider excipients such as macrogols as potential culprits. Unfortunately, this is rarely considered, and patients may have several severe reactions before macrogols (or other excipients) are suspected as in case 2. When anaphylaxis to the active drug is excluded in patients with reactions to unrelated drugs, there is a risk of labelling these cases “idiopathic anaphylaxis”, if the excipients in the drugs administered are not considered. In such cases the patient is at risk of future anaphylaxis on re-exposure to the excipients.

The sensitivity and specificity of skin tests and HR test evaluated in relation to the outcome of oral challenge to macrogol are unknown. As systemic reactions to skin testing with macrogols have been reported in several cases [6], it is important to titrate the skin test especially when including the high molecular weight macrogols, and furthermore, to extend observation time to 30 min as development of the wheal may be delayed [6]. Case 2 reacted to only high molecular weight macrogol in SPT, but was challenge positive to macrogol 3350. This finding supports the hypothesis, that clinical reactivity to macrogols is related to both amount and molecular weight, and although sensitization may occur to lower molecular weight macrogols, which more readily penetrate skin and mucosa, high molecular weight macrogols may subsequently elicit a response at lower concentrations [6]. This has implications for the skin test concentrations used, and it may be that SPT with higher molecular weight macrogols can be used to diagnose cases with reactions to lower molecular weight macrogols in the more distant past, as seemed to be the case in case 2. Another important finding from these cases is that skin reactivity may decrease or even be lost over time as has been shown regarding specific IgE for other allergens such as penicillin and chlorhexidine [7, 8]. Case 1 was skin tested 3 times during the first year, first the SPT was positive and then SPT reactivity diminished over time although challenge remained positive. Case 2 was not evaluated until 2 years after the last anaphylactic episode, and SPTs besides macrogol 20,000 were negative at this time, but challenge with macrogol 3350 (Movicol JuniorR) was positive. HR test was negative in all cases, and was not helpful to predict a reaction to macrogol in our cases. The same has been shown in other studies for both HR test and basophil activation test in relation to macrogol allergy [6].

Abbreviations

PEG:

polyethylene glycols

SPT:

skin prick tests

HR:

histamine release

References

  1. Fruijtier-Pölloth C. Safety assessment on polyethylene glycols (PEGs) and their derivatives as used in cosmetic products. Toxicology. 2005;214(1–2):1–38.

    Article  PubMed  Google Scholar 

  2. Dewachter P, Mouton-Faivre C. Anaphylaxis to macrogol 4000 after a parenteral corticoid injection. Allergy. 2005;60(5):705–6.

    Article  PubMed  Google Scholar 

  3. Bordere A, Stockman A, Boone B, Franki AS, Coppens MJ, Lapeere H, et al. A case of anaphylaxis caused by macrogol 3350 after injection of a corticosteroid. Contact Dermat. 2012;67(6):376–8.

    Article  Google Scholar 

  4. Sohy C, Vandenplas O, Sibille Y. Usefulness of oral macrogol challenge in anaphylaxis after intra-articular injection of corticosteroid preparation. Allergy. 2008;63(4):478–9.

    Article  CAS  PubMed  Google Scholar 

  5. Wenande EC, Skov PS, Mosbech H, Poulsen LK, Garvey LH. Inhibition of polyethylene glycol-induced histamine release by monomeric ethylene and diethylene glycol: a case of probable polyethylene glycol allergy. J Allergy Clin Immunol. 2013;131:1425–7.

    Article  CAS  PubMed  Google Scholar 

  6. Wenande E, Garvey LH. Immediate-type hypersensitivity to polyethylene glycols: a review. Clin Exp Allergy. 2016;46(7):907–22.

    Article  CAS  PubMed  Google Scholar 

  7. Hjortlund J, Mortz CG, Stage TB, Skov PS, Dahl R, Bindslev-Jensen C. Positive serum specific IgE has a short half-life in patients with penicillin allergy and reversal does not always indicate tolerance. Clin Transl Allergy. 2014;4:34.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Opstrup MS, Poulsen LK, Malling HJ, Jensen BM, Garvey LH. Dynamics of plasma levels of specific IgE in chlorhexidine allergic patients with and without accidental re-exposure. Clin Exp Allergy. 2016;46(8):1090–8.

    Article  CAS  PubMed  Google Scholar 

Download references

Authors’ contributions

CGM evaluated the patients, UBJ and CGM evaluated the literature, LHG provided the test concentrations for skin testing and UBJ prepared test substances for further evaluation of macrogol sensitization. NB and CGM drafted the manuscript. UBJ, HFK, CBJ and LHG critically revised the manuscript. All authors read and approved the final manuscript.

Acknowledgements

None.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

The data are in the patient files.

Ethics approval and consent to participate and publication

It is 3 cases therefore no Ethics approval was obtained. Written consent was obtained from all 3 patients to publish their case in anonymous form.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Charlotte G. Mortz.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Brandt, N., Garvey, L.H., Bindslev-Jensen, U. et al. Three cases of anaphylaxis following injection of a depot corticosteroid with evidence of IgE sensitization to macrogols rather than the active steroid. Clin Transl Allergy 7, 2 (2017). https://doi.org/10.1186/s13601-016-0138-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13601-016-0138-3

Keywords